Gas Metering Skids
Rockwin provides Skid-Mounted Systems, each engineered to our customer’s exact requirements for Natural Gas Metering, Pressure Regulation, Conditioning and Control. These skids have been supplied to, Gas Distribution / Gas Transportation Companies and End Users.
Customized Skids
Natural Gas Conditioning through Scrubber - Knock out drum / Filter Separator / Cartridge Filter.
Pressure Regulation through Direct Acting / Pilot Operated Globe or Axial Regulators / Pneumatic Control Valves.
Gas Pre-heating for high flow / high-pressure drop application
Single or Dual Stream Metering (RPD/Turbine/Orifice Type, Coriolis Mass Flow or Ultrasonic Meter) complying to required International/National Standards
Flow Computer / EVC / Modem / Control / SCADA Interface
Remote Set Point Monitoring
Gas Odorizing
Test procedures include:
- Hydrotest
- Radiography
- Dye Penetration
- Ultrasonic
- Magnetic Particle
- Pneumatic
- Charpy Impact
- Functional Test
- Point-to-point Electrical Control Panel Functional Testing